<menu id="ssssw"><table id="ssssw"></table></menu>
  • <rt id="ssssw"><samp id="ssssw"></samp></rt>
  • <bdo id="ssssw"></bdo>
  • Your Good Partner in Biology Research

    Human Cross Linked C-Telopeptide Of Type II Collagen ,CTX-Ⅱ ELISA Kit

    • 中文名称:
      人Ⅱ型胶原交联C端肽(CTX-Ⅱ)ELISA Kit
    • 货号:
      CSB-E14328h
    • 规格:
      96T/48T
    • 价格:
      ¥3600/¥2500
    • 其他:

    产品详情

    • 产品描述:

      This Human CTX- ELISA Kit was designed for the quantitative measurement of Human CTX- protein in serum, plasma, urine. It is a Sandwich ELISA kit, its detection range is 0.312 ng/mL-20 ng/mL and the sensitivity is 0.078 ng/mL.

    • 别名:
      Cross Linked C-Telopeptide Of Type 2 Collagen ,CTX-2,_x000D_ Cross Linked C-Telopeptide Of Type II Collagen ,CTX-II
    • 缩写:
      CTX-
    • 种属:
      Homo sapiens (Human)
    • 样本类型:
      serum, plasma, urine
    • 检测范围:
      0.312 ng/mL-20 ng/mL
    • 灵敏度:
      0.078 ng/mL
    • 反应时间:
      1-5h
    • 样本体积:
      50-100ul
    • 检测波长:
      450 nm
    • 研究领域:
      Others
    • 测定原理:
      quantitative
    • 测定方法:
      Sandwich
    • 说明书:
    • 精密度:
      Intra-assay Precision (Precision within an assay): CV%<8%      
      Three samples of known concentration were tested twenty times on one plate to assess.  
      Inter-assay Precision (Precision between assays): CV%<10%      
      Three samples of known concentration were tested in twenty assays to assess.    
                   
    • 线性度:
      To assess the linearity of the assay, samples were spiked with high concentrations of human CTX-Ⅱ in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
        Sample Serum(n=4)  
      1:1 Average % 93  
      Range % 86-98  
      1:2 Average % 100  
      Range % 96-104  
      1:4 Average % 99  
      Range % 92-105  
      1:8 Average % 92  
      Range % 87-98  
    • 回收率:
      The recovery of human CTX-Ⅱ spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
      Sample Type Average % Recovery Range  
      Serum (n=5) 96 90-100  
      EDTA plasma (n=4) 100 95-105  
                   
                   
    • 标准曲线:
      These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
      ng/ml OD1 OD2 Average Corrected  
      20 2.462 2.671 2.567 2.423  
      10 1.959 1.964 1.962 1.818  
      5 1.398 1.345 1.372 1.228  
      2.5 0.822 0.837 0.830 0.686  
      1.25 0.546 0.558 0.552 0.408  
      0.625 0.382 0.396 0.389 0.245  
      0.312 0.281 0.297 0.289 0.145  
      0 0.142 0.146 0.144    
    • 数据处理:
    • 货期:
      3-5 working days

    引用文献

    产品评价

    问答及客户评论

     常见问题解答
    Q:

    I want an citation/publication about Human Cross Linked C-Telopeptide Of Type II Collagen ,CTX-2 ELISA Kit CSB-E14328h in urine samples. Do you have any papers?

    A:
    Thanks for your inquiry.
    This kit can be used to test urine samples.
    We tested human normal urine samples before and the test value is 0.3--1.25ng/ml. Some customers said the detection rate is very low. I will send you the manual and published reference by e-mail to you soon.Pls let me know if you have any further questions. Thank you.


    1v1周青梅郑宣木天寥
    <menu id="ssssw"><table id="ssssw"></table></menu>
  • <rt id="ssssw"><samp id="ssssw"></samp></rt>
  • <bdo id="ssssw"></bdo>